J Magn Reson Imaging ; 2024 May 06.
Article in English | MEDLINE | ID: mdl-38708951

ABSTRACT

BACKGROUND: Irregular cardiac motion can render conventional segmented cine MRI nondiagnostic. Clustering has been proposed for cardiac motion binning and may be optimized for complex arrhythmias. PURPOSE: To develop an adaptive cluster optimization method for irregular cardiac motion, and to generate the corresponding time-resolved cine images. STUDY TYPE: Prospective. SUBJECTS: Thirteen with atrial fibrillation, four with premature ventricular contractions, and one patient in sinus rhythm. FIELD STRENGTH/SEQUENCE: Free-running balanced steady state free precession (bSSFP) with sorted golden-step, reference real-time sequence. ASSESSMENT: Each subject underwent both the sorted golden-step bSSFP and the reference Cartesian real-time imaging. Golden-step bSSFP images were reconstructed using the dynamic regularized adaptive cluster optimization (DRACO) method and k-means clustering. Image quality (4-point Likert scale), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), edge sharpness, and ventricular function were assessed. STATISTICAL TESTS: Paired t-tests, Friedman test, regression analysis, Fleiss' Kappa, Bland-Altman analysis. Significance level P < 0.05. RESULTS: The DRACO method had the highest percent of images with scores ≥3 (96% for diastolic frame, 93% for systolic frame, and 93% for multiphase cine) and the percentages were significantly higher compared with both the k-means and real-time methods. Image quality scores, SNR, and CNR were significantly different between DRACO vs. k-means and between DRACO vs. real-time. Cardiac function analysis showed no significant differences between DRACO vs. the reference real-time. CONCLUSION: DRACO with time-resolved reconstruction generated high quality images and has early promise for quantitative cine cardiac MRI in patients with complex arrhythmias including atrial fibrillation. TECHNICAL EFFICACY: Stage 2.

2.
J Magn Reson Imaging ; 2024 Mar 04.
Article in English | MEDLINE | ID: mdl-38436994

ABSTRACT

BACKGROUND: Balanced steady-state free precession (bSSFP) imaging is commonly used in cardiac cine MRI but prone to image artifacts. Ferumoxytol-enhanced (FE) gradient echo (GRE) has been proposed as an alternative. Utilizing the abundance of bSSFP images to develop a computationally efficient network that is applicable to FE GRE cine would benefit future network development. PURPOSE: To develop a variable-splitting spatiotemporal network (VSNet) for image reconstruction, trained on bSSFP cine images and applicable to FE GRE cine images. STUDY TYPE: Retrospective and prospective. SUBJECTS: 41 patients (26 female, 53 ± 19 y/o) for network training, 31 patients (19 female, 49 ± 17 y/o) and 5 healthy subjects (5 female, 30 ± 7 y/o) for testing. FIELD STRENGTH/SEQUENCE: 1.5T and 3T, bSSFP and GRE. ASSESSMENT: VSNet was compared to VSNet with total variation loss, compressed sensing and low rank methods for 14× accelerated data. The GRAPPA×2/×3 images served as the reference. Peak signal-to-noise-ratio (PSNR), structural similarity index (SSIM), left ventricular (LV) and right ventricular (RV) end-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction (EF) were measured. Qualitative image ranking and scoring were independently performed by three readers. Latent scores were calculated based on scores of each method relative to the reference. STATISTICS: Linear mixed-effects regression, Tukey method, Fleiss' Kappa, Bland-Altman analysis, and Bayesian categorical cumulative probit model. A P-value <0.05 was considered statistically significant. RESULTS: VSNet achieved significantly higher PSNR (32.7 ± 0.2), SSIM (0.880 ± 0.004), rank (2.14 ± 0.06), and latent scores (-1.72 ± 0.22) compared to other methods (rank >2.90, latent score < -2.63). Fleiss' Kappa was 0.52 for scoring and 0.61 for ranking. VSNet showed no significantly different LV and RV ESV (P = 0.938) and EF (P = 0.143) measurements, but statistically significant different (2.62 mL) EDV measurements compared to the reference. CONCLUSION: VSNet produced the highest image quality and the most accurate functional measurements for FE GRE cine images among the tested 14× accelerated reconstruction methods. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 1.

3.
NMR Biomed ; 37(4): e5091, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38196195

ABSTRACT

BACKGROUND: Despite the widespread use of cine MRI for evaluation of cardiac function, existing real-time methods do not easily enable quantification of ventricular function. Moreover, segmented cine MRI assumes periodicity of cardiac motion. We aim to develop a self-gated, cine MRI acquisition scheme with data-driven cluster-based binning of cardiac motion. METHODS: A Cartesian golden-step balanced steady-state free precession sequence with sorted k-space ordering was designed. Image data were acquired with breath-holding. Principal component analysis and k-means clustering were used for binning of cardiac phases. Cluster compactness in the time dimension was assessed using temporal variability, and dispersion in the spatial dimension was assessed using the Calinski-Harabasz index. The proposed and the reference electrocardiogram (ECG)-gated cine methods were compared using a four-point image quality score, SNR and CNR values, and Bland-Altman analyses of ventricular function. RESULTS: A total of 10 subjects with sinus rhythm and 8 subjects with arrhythmias underwent cardiac MRI at 3.0 T. The temporal variability was 45.6 ms (cluster) versus 24.6 ms (ECG-based) (p < 0.001), and the Calinski-Harabasz index was 59.1 ± 9.1 (cluster) versus 22.0 ± 7.1 (ECG based) (p < 0.001). In subjects with sinus rhythm, 100% of the end-systolic and end-diastolic images from both the cluster and reference approach received the highest image quality score of 4. Relative to the reference cine images, the cluster-based multiphase (cine) image quality consistently received a one-point lower score (p < 0.05), whereas the SNR and CNR values were not significantly different (p = 0.20). In cases with arrhythmias, 97.9% of the end-systolic and end-diastolic images from the cluster approach received an image quality score of 3 or more. The mean bias values for biventricular ejection fraction and volumes derived from the cluster approach versus reference cine were negligible. CONCLUSION: ECG-free cine cardiac MRI with data-driven clustering for binning of cardiac motion is feasible and enables quantification of cardiac function.


Subject(s)
Image Interpretation, Computer-Assisted , Magnetic Resonance Imaging, Cine , Humans , Magnetic Resonance Imaging, Cine/methods , Image Interpretation, Computer-Assisted/methods , Cardiac-Gated Imaging Techniques/methods , Ventricular Function , Cluster Analysis , Reproducibility of Results
4.
Clin Imaging ; 107: 110088, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38277858

ABSTRACT

PURPOSE: To evaluate relative and absolute utilization trends and practice patterns in the United States for MRA and CTA. METHODS: Using Medicare Part B physician payment databases (2013-2020), MRA and CTA interpreting physicians and exams were identified using the unique MRA and CTA Healthcare Common Procedure Coding System codes. The number of exams, physicians, demographics, use of contrast, and payments were summarized annually and analyzed to evaluate trends before and during the first year of the COVID-19 pandemic. RESULTS: From 2013 to 2019, the annual number of MRA exams performed decreased by 17.9 %, while the number of CTA exams increased by 90.3 %. The number of physicians interpreting MRA decreased in both hospital (-17.2 %) and outpatient (-7.5 %) environments. The number of physicians interpreting CTA increased in both hospital (+29.4 %) and outpatient (+54.3 %) environments. During the first year of the COVID-19 pandemic, MRA utilization decreased across all imaging environments by 25.0 % whereas CTA only decreased by 5.5 %. Intracranial MRA studies were most often performed without contrast, while contrast use for neck MRA was performed at similar rates as non-contrast exams. CONCLUSION: The overall utilization of MRA and the number of interpreting physicians are decreasing. On the other hand, CTA use and its number of interpreting physicians are increasing. During the first year of the COVID-19 pandemic, use of both MRA and CTA decreased, but the utilization of MRA decreased at five times the rate of CTA.


Subject(s)
COVID-19 , Medicare Part B , Aged , Humans , United States/epidemiology , Computed Tomography Angiography , Magnetic Resonance Angiography/methods , Pandemics , Magnetic Resonance Spectroscopy , COVID-19/epidemiology
5.
AIDS ; 38(3): 317-327, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-37788081

ABSTRACT

BACKGROUND: Proprotein convertase subtisilin/kexin 9 (PCSK9) raises low-density lipoprotein cholesterol (LDL-C) levels and is associated with inflammation, which is elevated in HIV and hepatitis C virus (HCV) infection. We compared PCSK9 levels in people with co-occurring HIV and HCV (HIV/HCV) vs. HIV alone, and evaluated the impact of HCV direct-acting antiviral (DAA) therapy on PCSK9. DESIGN: A prospective, observational cohort study. METHODS: Thirty-five adults with HIV/HCV and 37 with HIV alone were evaluated, all with HIV virologic suppression and without documented cardiovascular disease. Circulating PCSK9 and inflammatory biomarkers were measured at baseline and following HCV treatment or at week 52 (for HIV alone) and compared using Wilcoxon tests and Spearman correlations. RESULTS: At baseline, PCSK9 trended higher in HIV/HCV vs. HIV alone (307 vs. 284 ng/ml, P  = 0.06). Twenty-nine participants with HIV/HCV completed DAA therapy with sustained virologic response. PCSK9 declined from baseline to posttreatment 1 (median 7.3 weeks after end of therapy [EOT]) and posttreatment 2 (median 43.5 weeks after EOT), reaching levels similar to HIV alone; median within-person reduction was -60.5 ng/ml ( P  = 0.003) and -55.6 ng/ml ( P  = 0.02), respectively. Decline in PCSK9 correlated with decline in soluble (s)E-selectin and sCD163 ( r  = 0.64, P  = 0.002; r  = 0.58, P  = 0.008, respectively), but not with changes in LDL-C or other biomarkers. No significant change in PCSK9 occurred in the HIV alone group over 52 weeks. CONCLUSION: PCSK9 declined with DAA therapy in participants with HIV/HCV, correlating with declines in several inflammatory biomarkers but not LDL-C. Elevated PCSK9 with HCV may be linked to particular HCV-associated inflammatory pathways more so than cholesterol homeostasis.


Subject(s)
HIV Infections , Hepatitis C, Chronic , Hepatitis C , Adult , Humans , Proprotein Convertase 9 , Antiviral Agents/therapeutic use , Hepacivirus , Cholesterol, LDL , Prospective Studies , Hepatitis C, Chronic/complications , Hepatitis C, Chronic/drug therapy , HIV Infections/complications , HIV Infections/drug therapy , Proprotein Convertases/metabolism , Hepatitis C/complications , Hepatitis C/drug therapy , Inflammation/complications , Biomarkers
6.
J Am Heart Assoc ; : e030640, 2023 Nov 20.
Article in English | MEDLINE | ID: mdl-37982254

ABSTRACT

Standard of care echocardiography can have limited diagnostic accuracy in certain cases of fetal congenital heart disease. Prenatal cardiovascular magnetic resonance (CMR) imaging has potential to provide additional anatomic imaging information, including excellent soft tissue images in multiple planes, improving prenatal diagnostics and in utero hemodynamic assessment. We conducted a literature review of fetal CMR, including its development and implementation into clinical practice, and compiled and analyzed the results. Our findings included the fact that technological and innovative approaches are required to overcome some of the challenges in fetal CMR, in part due to the dynamic nature of the fetal heart. A number of reconstruction algorithms and cardiac gating strategies have been developed over time to improve fetal CMR image quality, allowing unique investigations into fetal hemodynamics, oxygenation, and growth. Studies demonstrate that incorporating CMR in the prenatal arena influences postnatal clinical management. With further refinement and experience, fetal CMR in congenital heart disease continues to evolve and demonstrate ongoing potential as a complementary imaging modality to fetal echocardiography in the care of these patients.

7.
Front Cardiovasc Med ; 10: 1107399, 2023.
Article in English | MEDLINE | ID: mdl-37469486

ABSTRACT

The ferumoxytol-enhanced 4D MR angiography with MUSIC (Multiphase Steady State Imaging with Contrast) technique provides a single data set that captures dynamic cardiovascular anatomy and ventricular function at the same time. Homogeneous opacification of all cardiovascular structures within the imaging volume allows full sequential segmental approach to the congenital heart diseases without any blind spots. The complex systemic and pulmonary venous anatomy is particularly well captured in the MUSIC. Cinematographic display of multiplanar sectional and 3D volume images is helpful in the morphological identification of the cardiac chambers, the assessment of the dynamic nature of the ventricular outflow tracts, and the assessment of the coronary arterial origins and courses.

8.
Pediatr Nephrol ; 38(7): 2179-2187, 2023 07.
Article in English | MEDLINE | ID: mdl-36508050

ABSTRACT

BACKGROUND: FGF23 mediates cardiac fibrosis through the activation of pro-fibrotic factors in in vitro models and is markedly elevated in kidney disease. Left atrial global longitudinal strain (LA GLS) derived by echocardiographic speckle-tracking measures longitudinal shortening of the LA walls, quantifies atrial performance and may enable detection of early LA remodeling in the setting of normal ventricular function. We hypothesized that LA GLS is abnormal in children on hemodialysis (HD) compared to healthy controls of comparable age/sex distribution and that, among HD patients, greater FGF23 levels are associated with abnormal LA GLS. METHODS: Clinical and echocardiographic data from 29 children receiving HD and 13 healthy controls were collected in a cross-sectional single-center study. Plasma FGF23 concentrations were measured using ELISA. The primary outcome was LA GLS measured using 2D speckle-tracking strain analysis. Linear regression analysis was used to investigate predictors of LA GLS in HD. RESULTS: Median dialysis vintage was 1.5 (IQR 0.5-4.3) years. Median intact FGF23 levels were substantially higher in the HD vs. control group (1206 [215, 4707] vs. 51 [43, 66.5] pg/ml; P = 0.0001), and LA GLS was 39.9% SD 11.6 vs. 32.8% SD 5.7 (P = 0.04). Among HD patients, higher FGF23 was associated with lower LA GLS (ß per unit Ln-FGF23: - 2.7; 95% CI slope - 5.4, - 0.1; P = 0.04 after adjustment for age, body size, and HD vintage. FGF23 was not associated with LA phasic reservoir, conduit, or contractile strain. CONCLUSIONS: In children on HD and preserved left ventricular ejection fraction, greater FGF23 is associated with lower LA GLS (indicative of impaired atrial performance). A higher resolution version of the Graphical abstract is available as Supplementary information.


Subject(s)
Atrial Fibrillation , Atrial Remodeling , Ventricular Dysfunction, Left , Humans , Child , Ventricular Function, Left , Stroke Volume , Cross-Sectional Studies , Renal Dialysis/adverse effects
9.
J Magn Reson Imaging ; 57(6): 1819-1829, 2023 06.
Article in English | MEDLINE | ID: mdl-36250695

ABSTRACT

BACKGROUND: The ultrasmall, superparamagnetic iron oxide (USPIO) nanoparticle ferumoxytol has unique applications in cardiac, vascular, and body magnetic resonance imaging (MRI) due to its long intravascular half-life and suitability as a blood pool agent. However, limited availability and high cost have hindered its clinical adoption. A new ferumoxytol generic, and the emergence of MoldayION as an alternative USPIO, represent opportunities to expand the use of USPIO-enhanced MRI techniques. PURPOSE: To compare in vitro and in vivo MRI relaxometry and enhancement of Feraheme, generic ferumoxytol, and MoldayION. STUDY TYPE: Prospective. ANIMAL MODEL: Ten healthy swine and six swine with artificially induced coronary narrowing underwent cardiac MRI. FIELD STRENGTH/SEQUENCE: 3.0 T; T1-weighted (4D-MUSIC, 3D-VIBE, 2D-MOLLI) and T2-weighted (2D-HASTE) sequences pre- and post-contrast. ASSESSMENT: We compared the MRI relaxometry of Feraheme, generic ferumoxytol, and MoldayION using saline, plasma, and whole blood MRI phantoms with contrast concentrations from 0.26 mM to 2.10 mM. In-vivo contrast effects on T1- and T2-weighted sequences and fractional intravascular contrast distribution volume in myocardium, liver, and spleen were evaluated. STATISTICAL TESTS: Analysis of variance and covariance were used for group comparisons. A P value <0.05 was considered statistically significant. RESULTS: The r1 relaxivities for Feraheme, generic ferumoxytol, and MoldayION in saline (22 °C) were 7.11 ± 0.13 mM-1  s-1 , 8.30 ± 0.29 mM-1  s-1 , 8.62 ± 0.16 mM-1  s-1 , and the r2 relaxivities were 111.74 ± 3.76 mM-1  s-1 , 105.07 ± 2.20 mM-1  s-1 , and 109.68 ± 2.56 mM-1  s-1 , respectively. The relationship between contrast concentration and longitudinal (R1) and transverse (R2) relaxation rate was highly linear in saline and plasma. The three agents produced similar in vivo contrast effects on T1 and T2 relaxation time-weighted sequences. DATA CONCLUSION: Relative to clinically approved ferumoxytol formulations, MoldayION demonstrates minor differences in in vitro relaxometry and comparable in vivo MRI characteristics. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 1.


Subject(s)
Ferrosoferric Oxide , Magnetite Nanoparticles , Animals , Swine , Contrast Media , Prospective Studies , Magnetic Resonance Imaging/methods , Dextrans
10.
Magn Reson Med ; 89(4): 1557-1566, 2023 04.
Article in English | MEDLINE | ID: mdl-36382769

ABSTRACT

PURPOSE: To investigate model-fitted fractional myocardial blood volume (fMBV) derived from ferumoxytol-enhanced MRI as a measure of myocardial tissue hypoperfusion at rest. METHODS: We artificially induced moderate to severe focal coronary stenosis in the left anterior descending artery of 19 swine by percutaneous delivery of a 3D-printed coronary implant. Using the MOLLI pulse sequence, we acquired T1 maps at 3 T after multiple incremental ferumoxytol doses (0.0-4.0 mg/kg). We computed pixel-wise fMBV using a multi-compartmental modeling approach in 19 ischemic swine and 4 healthy swine. RESULTS: Ischemic myocardial segments showed a mean MRI-fMBV of 11.72 ± 3.00%, compared with 8.23 ± 2.12% in remote segments and 8.38 ± 2.23% in normal segments. Ischemic segments showed a restricted transvascular water-exchange rate (ki  = 15.32 ± 8.69 s-1 ) relative to remote segments (ki  = 17.78 [11.60, 26.36] s-1 ). A mixed-effects model found significant difference in fMBV (p = 0.002) and water-exchange rate (p < 0.001) between ischemic and remote myocardial regions after adjusting for biological sex and slice location. Analysis of fMBV as a predictor of impaired myocardial contractility using receiver operating characteristics showed an area under the curve of 0.89 (95% confidence interval [CI] 0.80, 0.95). An MRI-fMBV threshold of 9.60% has a specificity of 90.0% (95% CI 76.3, 97.2) and a sensitivity of 72.5% (95% CI 56.1, 83.4) for prediction of impaired myocardial contractility. CONCLUSIONS: Model-fitted fMBV derived from ferumoxytol-enhanced MRI can distinguish regions of ischemia from remote myocardium in a swine model of myocardial hypoperfusion.


Subject(s)
Coronary Artery Disease , Myocardial Ischemia , Animals , Swine , Ferrosoferric Oxide , Myocardium , Myocardial Ischemia/diagnostic imaging , Magnetic Resonance Imaging , Blood Volume , Ischemia , Water
11.
Am J Cardiol ; 186: 50-57, 2023 01 01.
Article in English | MEDLINE | ID: mdl-36343446

ABSTRACT

Human immunodeficiency virus (HIV) infection is associated with subclinical cardiomyopathy, diastolic dysfunction, and increased risk of cardiovascular death. However, the relationship between left atrial (LA) mechanics and left ventricular (LV) diastolic function has not been evaluated in people living with HIV (PLWH) relative to HIV-uninfected (HIV-) controls. This is a multicenter, cross-sectional cohort analysis using the HIV Cardiovascular Disease substudy of the Veterans Aging Cohort Study database, which aimed to examine a cohort of PLWH and HIV- veterans without known cardiovascular disease. A total of 277 subjects (180 PLWH, 97 HIV-) with echocardiograms were identified. LV and LA phasic strain were derived and diastolic function was evaluated. Relationship between LA strain, LV strain, and the degree of diastolic dysfunction were assessed using analysis of variance and ordinal logistic regression with propensity weighting. In the PLWH cohort, 91.7% were on antiretroviral therapy and 86.1% had HIV viral loads <500 copies/ml. The mean (± SD) duration of infection was 9.7 ± 4.9 years. Relative to HIV- veterans, PLWH did not differ in LA mechanics and proportion of diastolic dysfunction (p = 0.31). Using logistic regression with propensity weighting, we found no association between HIV status and degree of diastolic dysfunction. In both cohorts, LA reservoir strain and LA conduit strain were inversely and independently associated with the degree of diastolic dysfunction. Compared with HIV- veterans, PLWH who are primarily virally suppressed and antiretroviral-treated did not differ in LA strain or LV diastolic dysfunction. If confirmed in other cohorts, HIV viral suppression may curtail adverse alterations in cardiac structure and function.


Subject(s)
HIV Infections , Ventricular Dysfunction, Left , Veterans , Humans , Cohort Studies , Cross-Sectional Studies , Heart Atria/diagnostic imaging , Ventricular Function, Left , Aging , HIV Infections/complications , HIV Infections/epidemiology , HIV
12.
Children (Basel) ; 9(12)2022 Nov 24.
Article in English | MEDLINE | ID: mdl-36553257

ABSTRACT

Cardiac magnetic resonance imaging and angiography have a crucial role in the diagnostic evaluation and follow up of pediatric and adult patients with congenital heart disease. Although much of the information required of advanced imaging studies can be provided by standard gadolinium-enhanced magnetic resonance imaging, the limitations of precise bolus timing, long scan duration, complex imaging protocols, and the need to image small structures limit more widespread use of this modality. Recent experience with off-label diagnostic use of ferumoxytol has helped to mitigate some of these barriers. Approved by the U.S. FDA for intravenous treatment of anemia, ferumoxytol is an ultrasmall superparamagnetic iron oxide nanoparticle that has a long blood pool residence time and high relaxivity. Once metabolized by macrophages, the iron core is incorporated into the reticuloendothelial system. In this work, we aim to summarize the evolution of ferumoxytol-enhanced cardiovascular magnetic resonance imaging and angiography and highlight its many applications for congenital heart disease.

13.
J Clin Neurosci ; 105: 131-136, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36183571

ABSTRACT

BACKGROUND: Current methods for quantitative assessment of cerebral small vessel disease (CSVD) ignore critical aspects of the disease, namely lesion type and regionality. We developed and tested a new scoring system for CSVD, "regional Cerebral Small Vessel Disease" (rCSVD) based on regional assessment of magnetic resonance imaging (MRI) features. METHODS: 141 patients were retrospectively included with a derivation cohort of 46 consecutive brain MRI exams and a validation cohort of 95 patients with known cerebrovascular disease. We compared the predictive value of rCSVD against existing scoring methods. We determined the predictive value of rCSVD score for all-cause mortality and recurrent strokes. RESULTS: 46 (44 male) veteran patients (age: 66-93 years), were included for derivation of the rCSVD score. A non-overlapping validation cohort consisted of 95 patients (89 male; age: 34-91 years) with known cerebrovascular disease were enrolled. Based on ROC analysis with comparison of AUC (Area Under the Curve), "rCSVD" score performed better compared to "total SVD score" and Fazekas score for predicting all-cause mortality (0.75 vs 0.68 vs 0.69; p = 0.046). "rCSVD" and total SVD scores were predictive of recurrent strokes in our validation cohort (p-values 0.004 and 0.001). At a median of 5.1 years (range 2-17 years) follow-up, Kaplan-Meier survival analysis demonstrated an rCSVD score of 2 to be a significant predictor of all-cause-mortality. CONCLUSION: "rCSVD" score can be derived from routine brain MRI, has value in risk stratification of patients at risk of CSVD, and has potential in clinical trials once fully validated in a larger patient cohort.


Subject(s)
Cerebral Small Vessel Diseases , Stroke , Adult , Aged , Aged, 80 and over , Brain , Cerebral Small Vessel Diseases/diagnostic imaging , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Retrospective Studies , Stroke/diagnostic imaging
14.
Quant Imaging Med Surg ; 12(9): 4377-4389, 2022 Sep.
Article in English | MEDLINE | ID: mdl-36060580

ABSTRACT

Background: Quantitative ventricular volumetry and function are important in the management of congenital heart disease (CHD). Ferumoxytol-enhanced (FE) 4D multiphase, steady state imaging with contrast enhancement (MUSIC) enables high-resolution, 3D cardiac phase-resolved magnetic resonance imaging (MRI) of the beating heart and extracardiac vessels in a single acquisition and without concerns about renal impairment. We aim to evaluate the semi-automatic quantification of ventricular volumetry and function of 4D MUSIC MRI using 2D and 3D software platforms. Methods: This HIPAA-compliant and IRB-approved study prospectively recruited 50 children with CHD (3 days to 18 years) who underwent 4D MUSIC MRI at 3.0T between 2013-2017 for clinical indications. Each patient was either intubated in the neonatal intensive care unit (NICU) or underwent general anesthesia at MRI suite. For 2D analysis, we reformatted MUSIC images in Digital Imaging and Communications in Medicine (DICOM) format into ventricular short-axis slices with zero interslice gap. For 3D analysis, we imported DICOMs into a commercially available 3D software platform. Using semi-automatic thresholding, we quantified biventricular volume and ejection fraction (EF). We assessed the bias between MUSIC-derived 2D vs. 3D measurements and correlation between MUSIC vs. conventional 2D balanced steady-state free precession (bSSFP) cine images. We evaluated intra- and inter-observer agreement. Results: There was a high degree of correlation between MUSIC-derived volumetric and functional measurements using 2D vs. 3D software (r=0.99, P<0.001). Volumes derived using 3D software platforms were larger than 2D by 0.2 to 2.0 mL/m2 whereas EF measurements were higher by 1.2-3.0%. MUSIC volumetric and functional measures derived from 2D and 3D software platforms corresponded highly with those derived from multi-slice SSFP cine images (r=0.99, P<0.001). The mean difference in volume for reformatted 4D MUSIC relative to bSSFP cine was 1.5 to 3.9 mL/m2. Intra- and inter-observer reliability was excellent. Conclusions: Accurate and reliable ventricular volumetry and function can be derived from FE 4D MUSIC MRI studies using commercially available 2D and 3D software platforms. If fully validated in multicenter studies, the FE 4D-MUSIC pulse sequence may supercede conventional multislice 2D cine cardiovascular MRI acquisition protocols for functional evaluation of children with complex CHD.

15.
Magn Reson Med ; 88(4): 1748-1763, 2022 10.
Article in English | MEDLINE | ID: mdl-35713184

ABSTRACT

PURPOSE: To develop a free-breathing, non-electrocardiogram technique for simultaneous myocardial T1 , T2 , T2 *, and fat-fraction (FF) mapping in a single scan. METHODS: The MR Multitasking framework is adapted to quantify T1 , T2 , T2 *, and FF simultaneously. A variable TR scheme is developed to preserve temporal resolution and imaging efficiency. The underlying high-dimensional image is modeled as a low-rank tensor, which allows accelerated acquisition and efficient reconstruction. The accuracy and/or repeatability of the technique were evaluated on static and motion phantoms, 12 healthy volunteers, and 3 patients by comparing to the reference techniques. RESULTS: In static and motion phantoms, T1 /T2 /T2 */FF measurements showed substantial consistency (R > 0.98) and excellent agreement (intraclass correlation coefficient > 0.93) with reference measurements. In human subjects, the proposed technique yielded repeatable T1 , T2 , T2 *, and FF measurements that agreed with those from references. CONCLUSIONS: The proposed free-breathing, non-electrocardiogram, motion-resolved Multitasking technique allows simultaneous quantification of myocardial T1 , T2 , T2 *, and FF in a single 2.5-min scan.


Subject(s)
Heart , Image Interpretation, Computer-Assisted , Heart/diagnostic imaging , Humans , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Motion , Myocardium , Phantoms, Imaging , Reproducibility of Results
17.
Magn Reson Med ; 87(2): 984-998, 2022 02.
Article in English | MEDLINE | ID: mdl-34611937

ABSTRACT

PURPOSE: To automate the segmentation of the peripheral arteries and veins in the lower extremities based on ferumoxytol-enhanced MR angiography (FE-MRA). METHODS: Our automated pipeline has 2 sequential stages. In the first stage, we used a 3D U-Net with local attention gates, which was trained based on a combination of the Focal Tversky loss with region mutual loss under a deep supervision mechanism to segment the vasculature from the high-resolution FE-MRA datasets. In the second stage, we used time-resolved images to separate the arteries from the veins. Because the ultimate segmentation quality of the arteries and veins relies on the performance of the first stage, we thoroughly evaluated the different aspects of the segmentation network and compared its performance in blood vessel segmentation with currently accepted state-of-the-art networks, including Volumetric-Net, DeepVesselNet-FCN, and Uception. RESULTS: We achieved a competitive F1 = 0.8087 and recall = 0.8410 for blood vessel segmentation compared with F1 = (0.7604, 0.7573, 0.7651) and recall = (0.7791, 0.7570, 0.7774) obtained with Volumetric-Net, DeepVesselNet-FCN, and Uception. For the artery and vein separation stage, we achieved F1 = (0.8274/0.7863) in the calf region, which is the most challenging region in peripheral arteries and veins segmentation. CONCLUSION: Our pipeline is capable of fully automatic vessel segmentation based on FE-MRA without need for human interaction in <4 min. This method improves upon manual segmentation by radiologists, which routinely takes several hours.


Subject(s)
Ferrosoferric Oxide , Magnetic Resonance Imaging , Angiography , Arteries/diagnostic imaging , Humans , Image Processing, Computer-Assisted , Veins/diagnostic imaging
18.
Tissue Eng Part B Rev ; 28(3): 633-664, 2022 06.
Article in English | MEDLINE | ID: mdl-34210148

ABSTRACT

The field of tissue engineering continues to advance, sometimes in exponential leaps forward, but also sometimes at a rate that does not fulfill the promise that the field imagined a few decades ago. This review is in part a catalog of success in an effort to inform the process of innovation. Tissue engineering has recruited new technologies and developed new methods for engineering tissue constructs that can be used to mitigate or model disease states for study. Key to this antecedent statement is that the scientific effort must be anchored in the needs of a disease state and be working toward a functional product in regenerative medicine. It is this focus on the wildly important ideas coupled with partnered research efforts within both academia and industry that have shown most translational potential. The field continues to thrive and among the most important recent developments are the use of three-dimensional bioprinting, organ-on-a-chip, and induced pluripotent stem cell technologies that warrant special attention. Developments in the aforementioned areas as well as future directions are highlighted in this article. Although several early efforts have not come to fruition, there are good examples of commercial profitability that merit continued investment in tissue engineering. Impact statement Tissue engineering led to the development of new methods for regenerative medicine and disease models. Among the most important recent developments in tissue engineering are the use of three-dimensional bioprinting, organ-on-a-chip, and induced pluripotent stem cell technologies. These technologies and an understanding of them will have impact on the success of tissue engineering and its translation to regenerative medicine. Continued investment in tissue engineering will yield products and therapeutics, with both commercial importance and simultaneous disease mitigation.


Subject(s)
Bioprinting , Tissue Engineering , Humans , Printing, Three-Dimensional , Regenerative Medicine/methods , Tissue Engineering/methods
19.
Br J Radiol ; 94(1125): 20210430, 2021 Sep 01.
Article in English | MEDLINE | ID: mdl-34415199

ABSTRACT

OBJECTIVES: To assess the feasibility of a rapid, focused ferumoxytol-enhanced MR angiography (f-FEMRA) protocol in patients with claustrophobia. METHODS: In this retrospective study, 13 patients with claustrophobia expressed reluctance to undergo conventional MR angiography, but agreed to a trial of up to 10 min in the scanner bore and underwent f-FEMRA. Thirteen matched control patients who underwent gadolinium-enhanced MR angiography (GEMRA) were identified for comparison of diagnostic image quality. For f-FEMRA, the time from localizer image acquisition to completion of the angiographic acquisition was measured. Two radiologists independently scored images on both f-FEMRA and GEMRA for arterial and venous image quality, motion artefact and diagnostic confidence using a 5-point scale, five being best. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in the aorta and IVC were measured. The Wilcoxon rank-sum test, one-way ANOVA with Tukey correction and two-tailed t tests were utilized for statistical analyses. RESULTS: All scans were diagnostic and assessed with high confidence (scores ≥ 4). Average scan time for f-FEMRA was 6.27 min (range 3.56 to 10.12 min), with no significant difference between f-FEMRA and GEMRA in diagnostic confidence (4.86 ± 0.24 vs 4.69 ± 0.25, p = 0.13), arterial image quality (4.62 ± 0.57 vs 4.65 ± 0.49, p = 0.78) and motion artefact score (4.58 ± 0.49 vs 4.58 ± 0.28, p > 0.99). f-FEMRA scored significantly better for venous image quality than GEMRA (4.62 ± 0.42 vs 4.19 ± 0.56, p = 0.04). CNR in the IVC was significantly higher for steady-state f-FEMRA than GEMRA regardless of the enhancement phase (p < 0.05). CONCLUSIONS: Comprehensive vascular MR imaging of the thorax, abdomen and pelvis can be completed in as little as 5 min within the magnet bore using f-FEMRA, facilitating acceptance by patients with claustrophobia and streamlining workflow. ADVANCES IN KNOWLEDGE: A focused approach to vascular imaging with ferumoxytol can be performed in patients with claustrophobia, limiting time in the magnet bore to 10 min or less, while acquiring fully diagnostic images of the thorax, abdomen and pelvis.


Subject(s)
Contrast Media , Ferrosoferric Oxide , Image Enhancement/methods , Magnetic Resonance Angiography/methods , Magnetic Resonance Angiography/psychology , Phobic Disorders/psychology , Cohort Studies , Feasibility Studies , Female , Humans , Male , Middle Aged , Reproducibility of Results , Retrospective Studies , Time
20.
Magn Reson Med ; 86(5): 2666-2683, 2021 11.
Article in English | MEDLINE | ID: mdl-34254363

ABSTRACT

PURPOSE: Develop a novel three-dimensional (3D) generative adversarial network (GAN)-based technique for simultaneous image reconstruction and respiratory motion compensation of 4D MRI. Our goal was to enable high-acceleration factors 10.7X-15.8X, while maintaining robust and diagnostic image quality superior to state-of-the-art self-gating (SG) compressed sensing wavelet (CS-WV) reconstruction at lower acceleration factors 3.5X-7.9X. METHODS: Our GAN was trained based on pixel-wise content loss functions, adversarial loss function, and a novel data-driven temporal aware loss function to maintain anatomical accuracy and temporal coherence. Besides image reconstruction, our network also performs respiratory motion compensation for free-breathing scans. A novel progressive growing-based strategy was adapted to make the training process possible for the proposed GAN-based structure. The proposed method was developed and thoroughly evaluated qualitatively and quantitatively based on 3D cardiac cine data from 42 patients. RESULTS: Our proposed method achieved significantly better scores in general image quality and image artifacts at 10.7X-15.8X acceleration than the SG CS-WV approach at 3.5X-7.9X acceleration (4.53 ± 0.540 vs. 3.13 ± 0.681 for general image quality, 4.12 ± 0.429 vs. 2.97 ± 0.434 for image artifacts, P < .05 for both). No spurious anatomical structures were observed in our images. The proposed method enabled similar cardiac-function quantification as conventional SG CS-WV. The proposed method achieved faster central processing unit-based image reconstruction (6 s/cardiac phase) than the SG CS-WV (312 s/cardiac phase). CONCLUSION: The proposed method showed promising potential for high-resolution (1 mm3 ) free-breathing 4D MR data acquisition with simultaneous respiratory motion compensation and fast reconstruction time.


Subject(s)
Heart , Magnetic Resonance Imaging , Artifacts , Feasibility Studies , Heart/diagnostic imaging , Humans , Image Processing, Computer-Assisted , Motion